- Content
SC-UV1000 Spectrophotometer (with RBPR function)
Features
2.2.1 Automatic control function
1) Self-check and wavelength auto-calibrate when power on.
2) Auto-set wavelength position.
3) Auto-switch filter.
4) Auto-switch light source.
5) Auto-optimize light source switching point.
6) Display error messages.
2.2.2 Analytical operation and data processing function
1) Photometric measurement.
2) Spectrometric scanning.
3) Quantitative analysis.
4) Chemical kinetics measurement.
5) Multi-wavelength measurement.
6) RBPR / TARI pesticide residue analysis
7) Spectrogram zoom, save and load.
Technical specifications

Features
2.2.1 Automatic control function
1) Self-check and wavelength auto-calibrate when power on.
2) Auto-set wavelength position.
3) Auto-switch filter.
4) Auto-switch light source.
5) Auto-optimize light source switching point.
6) Display error messages.
2.2.2 Analytical operation and data processing function
1) Photometric measurement.
2) Spectrometric scanning.
3) Quantitative analysis.
4) Chemical kinetics measurement.
5) Multi-wavelength measurement.
6) RBPR / TARI pesticide residue analysis
7) Spectrogram zoom, save and load.
Technical specifications
Model | UV1000T | UV1000S |
Monochromator | Split beam, C-T type, 1200 L/mm grating | |
Detector | Silicon detector for ultraviolet visible region | |
Display | 7 inch TFT colored capacitive touch screen | |
Wavelength calibration | Automatic at start | |
Wavelength display | 0.1nm | |
Light source | Deuterium discharge tube, Tungsten lamp(20W/12V) | |
Lamp change point | Can be set, 294 nm ~ 365 nm | |
Wavelength range | 190 ~ 1100nm | |
Slit width | 1.8nm | |
Wavelength accuracy | ±0.3nm | ±0.5nm |
Wavelength repeatability | 0.1nm | 0.2nm |
Measurement range | 0 ~ 200%T, -0.301 ~ 4.000Abs, 0 ~ 9999C, 0 ~ 9999F | |
Photometric accuracy | ±0.2%T(0-100%T) ±0.002Abs(0-0.5Abs) ±0.004Abs(0.5-1.0Abs) |
±0.3%T(0-100%T) ±0.002Abs(0-0.5Abs) ±0.004Abs(0.5-1.0Abs) |
Photometric repeatability | 0.1%T(0-100%T), ±0.001Abs(0-0.5Abs), ±0.002Abs(0.5-1Abs) | |
Stray light | 0.03%T (at 220nm, 360nm, 420nm) | 0.05%T(at 220nm, 360nm, 420nm) |
Baseline flatness | ±0.001Abs | ±0.002Abs |
Stability | 0.001Abs / hour (at 500 nm, after 2 hours energization) | 0.001Abs / hour (at 500 nm, after 2 hours energization) |
RBPR Function | YES | YES |
Scan speed | 3 modes: fast, median and slow | |
Data output | Digital, USB port | |
Sample holder | Automatic sample holder with 8-positions (10mm optical pathlength) | |
Power | 220V±10% 50Hz 85VA / 110V±10% 60Hz 85VA | |
Actual dimensions | 545 W x 450 D x 235 H mm, (21.5 W x 17.8 D x 9.3 H in) | |
Shipping dimensions | 660 W x 560 D x 400 H mm, (26.0 W x 22.1 D x 15.8 H in) | |
Net weight | 17.0 Kg (37.5 lbs) | |
Gross weight | 26.0 Kg (57.3 lbs) |